Martijn Kool
Specifications
T75 Cryogenic ISO Tanks
The T75 cryogenic tank container is constructed with precision to handle the challenges posed by transporting and storing:
liquid nitrogen (LIN)
liquid oxide (LOX)
liquid argon (LAR)
liquid carbon dioxide (LCO2)
liquid nitrous oxide (LN2O)
Compliant with international standards, these containers typically have a capacity ranging from 20,000 to 24,000 liters, making them ideal for the efficient and safe transport of cryogenic materials.
The T75 finds its primary application in the gas and chemical industry but can also be used in the medical field and for other healthcare purposes.
Our T75 cryogenic tank container also plays a role in the efficient transport of a.o. liquefied natural gas. Continuous re-use of our T75 containers contributes to reducing greenhouse gas emissions, providing an eco-friendly alternative for energy transportation.
Should this tank container be interesting for your company, feel free to contact us anytime.
Certifications
At Meeberg ISO Tanks & Containers, we ensure all our new & second hand tank containers are delivered with certifications from leading organizations such as Lloyd's Register (LR), American Bureau of Shipping (ABS), Bureau Veritas (BV) and SGS. This guarantees the highest standards of safety, quality, and reliability for your operations.
We offer the following types of certifications for our clients:
2.5-Year Test for ISO Tank Containers
The 2.5-year test, also known as the intermediate inspection, is a crucial part of maintaining ISO tank containers. Conducted halfway through the 5-year certification period, this test ensures that the tank remains in safe and operable condition.Key aspects of the 2.5-year test include:
Visual Inspection: A thorough visual check of the tank's exterior and interior surfaces to identify any signs of wear, corrosion, or damage.
Leak Test: Conducting a leak test to ensure the tank's integrity and that there are no leaks that could compromise safety.
Valve and Gasket Checks: Inspecting all valves and gaskets for functionality and integrity, replacing any that are worn or damaged.
Structural Integrity Assessment: Verifying that the frame and overall structure of the tank meet the required safety standards.
5-Year Test for ISO Tank Containers
This test is more extensive than the intermediate 2.5-year test and involves a detailed assessment of the tank's condition and performance.Key aspects of the 5-year test include:
Internal and External Inspection: A thorough examination of both the interior and exterior surfaces of the tank to identify any corrosion, wear, or damage that could affect the tank’s integrity.
Hydrostatic Pressure Test: This test involves filling the tank with water and pressurizing it to check for leaks and ensure the tank can withstand its maximum working pressure without any issues.
Ultrasonic Thickness Testing: Measures wall thickness to ensure structural integrity.
Valve and Fitting Inspection: Checking all valves, fittings, and seals to ensure they are in good working condition.
Frame and Structural Assessment: Verifies compliance with ISO and CSC standards.
Documentation and Certification: Updating the tank’s certification to reflect that it has passed the 5-year test, ensuring it is compliant with relevant international standards such as IMDG, ADR, RID, and CFR 49.
CSC Test for ISO Tank Containers
The CSC (International Convention for Safe Containers) test ensures ISO tank containers meet international safety standards for transport. Key aspects include:
Structural Integrity Inspection: Checking the frame and structural components for strength and stability.
Safety and Security Checks: Ensuring all locking mechanisms and securing devices are functional.
Identification and Marking Verification: Confirming the presence and legibility of the CSC plate and other required labels.
Dimensional Accuracy: Ensuring the container meets ISO dimensional standards.
Damage and Wear Assessment: Identifying any signs of damage or corrosion.
Maintenance Record Review: Checking that maintenance and previous inspections are documented.